70 SPARC Enterprise T5440 Server Service Manual July 2009
Read the section, “Safety Information” on page 59.
Power off the server using one of the methods described in the section, “Powering
Off the System” on page 63.
“Extend the Server to the Maintenance Position” on page 66
“Perform Electrostatic Discharge Antistatic Prevention Measures” on page 69
1. Loosen the two captive No. 2 Phillips screws at the rear edge of the top panel.
2. Slide the top cover to the rear about 0.5 inch (12.7 mm).
3. Remove the top cover.
Lift up and remove the cover.
Caution If the top cover is removed before the server is powered off, the server
will immediately disable the front panel Power button and shut down. After such an
event, you must replace the top cover and use the poweron command to power on
the server. See “Power On the Server” on page 153.
FIGURE: Removing the Top Cover
Zobrazit stránku 95