Fujitsu SPARC T5440 Uživatelský manuál Strana 182

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 212
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 181
160 SPARC Enterprise T5440 Server Service Manual June 2011
“Servicing CMP/Memory Modules” on page 102
“Servicing FB-DIMMs” on page 108
I/O Connections to CMP/Memory
Modules
Each PCIe slot and onboard I/O device is connected to one CMP module. Device
address is dependent on system configuration. See CMP Number on page 168 and
CMP Number on page 169 for more information.
If a CMP module fails, the onboard devices and slots directly connected to it become
unavailable. Recovery of the I/O services connected to the failed CMP requires I/O
node reconfiguration.
For example, in a 4P system, if CMP0 goes offline, the following devices become
unavailable:
PCIe0
PCIe1
Onboard hard drives
In this failure scenario, the system is unable to boot from internal drives.
Similarly, if CMP1 goes offline, the following devices become unavailable:
PCIe4
PCIe5
Onboard network devices
Related Information
“System Bus Topology” on page 167
“I/O Fabric in 2P Configuration” on page 168
“I/O Fabric in 4P Configuration” on page 169
Zobrazit stránku 181
1 2 ... 177 178 179 180 181 182 183 184 185 186 187 ... 211 212