Fujitsu SPARC ENTERPRISE M3000 Uživatelský manuál Strana 197

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 212
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 196
Appendix D UPS Controller D-3
D.3 Configuration of Signal Lines
This section provides the signal definitions.
FIGURE D-2 shows the configuration of signal lines when the UPS is connected.
FIGURE D-2 Connection Between the Server and UPS
TABLE D-1 Signal Line Definitions
Signal name Definitions Pin number Remarks
*BPS/*UALM Indicates a UPS error. 6 Normal state: Off
Abnormal state: On
*BTL Indicates that the battery level of the UPS has
decreased and warns that battery power will be
unavailable after a certain period of time has
elapsed.
7 Normal state: Off
Abnormal warning:
On
(Note 1)
*BTL
*BPS/*UALM
*ACOFF
SG
UPS cableUPS Server
7
6
9
5
Zobrazit stránku 196
1 2 ... 192 193 194 195 196 197 198 199 200 201 202 ... 211 212

Komentáře k této Příručce

Žádné komentáře