Fujitsu M3000 Uživatelský manuál Strana 71

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 76
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 70
Appendix B Troubleshooting B-7
Example of showhardconf -u command execution
B.3.2 Using the showlogs Command
The showlogs command displays the contents of the specified log in order of
timestamp. The displayed contents begin from the oldest date. The showlogs
command displays the following logs:
Error log
Power log
Event log
Temperature and humidity record
Monitoring message log
Console message log
Panic message log
IPL message log
XSCF> showhardconf -u
SPARC Enterprise M3000; Memory_Size:8 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU_A | 1 |
| CPU | ( 1) |
| Freq:2.520 GHz; | ( 1) |
| MEM | 8 |
| Type:1A; Size:1 GB; | ( 8) |
| OPNL | 1 |
| PSU | 2 |
| FANBP_B | 1 |
| FAN_A | 2 |
+-----------------------------------+------------+
XSCF>